Manuals · Jul 05, 2026 · 1 min read
SLWF-11 Manual · 7. Troubleshooting
Symptom Likely cause Fix No power / device dead Wrong voltage, loose or reversed wiring, bad adapter Verify supply, check connections, try another source/cable Powers on but LEDs dark Data/GND wiring…
SLWF-11 User Manual — Part 7 of 10
| Symptom | Likely cause | Fix |
|---|---|---|
| No power / device dead | Wrong voltage, loose or reversed wiring, bad adapter | Verify supply, check connections, try another source/cable |
| Powers on but LEDs dark | Data/GND wiring or wrong LED type/count | Check Data + shared GND, set LED type/count in WLED |
No WLED-AP hotspot | Already joined a previous network | Reset Wi-Fi (WLED recovery) to re-broadcast the AP |
| Won't join home Wi-Fi | Wrong credentials or 5 GHz network | Verify SSID/password; use a 2.4 GHz SSID |
| Flicker / wrong colors | Voltage drop, poor ground, color-order mismatch | Power injection, common GND, set correct color order |
| Only first LEDs light | Insufficient power or wrong count | Larger supply; set correct LED count |
| Web UI unreachable | Corrupt firmware | Re-flash the correct ESP8266 build over USB |
| IR remote not responding | IR not enabled in WLED | Enable IR (GPIO4) and select the correct remote type |
Still stuck? Contact SMLIGHT support with your issue description and purchase details.